ChemicalsProduct information

GlycoFlow 42 – Premixed Ethylene Glycol Antifreeze & Heat Transfer Coolant (42%)

GlycoFlow 42 is a professionally formulated premixed ethylene glycol coolant containing approximately 42% ethylene glycol blended with high-quality water and a proprietary corrosion inhibitor package. The formulation provides dependable freeze protection, heat transfer efficiency, and long-term corrosion protection for multi-metal cooling systems. Ethylene glycol-based coolants are widely used…

Purity / Grade
Industrial Grade
Price & supply

Order this chemical

Was price₨ 19,000Now price₨ 17,500
Packing / Packaging
25 L

Delivery charges are confirmed at checkout for your order quantity and destination.

Request quote
Technical reference

Specifications

Synonyms
Ethylene Glycol Coolant
Premixed Antifreeze
HVAC Heat Transfer Fluid
Chilled Water Coolant
Closed-Loop Cooling Fluid
Industrial Glycol Coolant
Heat Transfer Fluid 42%
Ready-to-Use Glycol Solution
Appearance
Clear liquid

Uses & applications

Usage notes

Ready to use; do not dilute.
Fill only clean, flushed cooling systems.
Remove trapped air during filling.
Periodically inspect coolant condition and system pH.
Replace coolant according to equipment manufacturer's maintenance schedule.
Avoid contamination with other coolant chemistries.
Compatible Materials
Carbon Steel
Stainless Steel
Copper
Brass
Cast Iron
Aluminum (where approved by equipment manufacturer)
HVAC System Components
Heat Exchangers




Safety Instructions

⚠ Harmful if swallowed.

⚠ Avoid contact with eyes and prolonged skin contact.

⚠ Wear suitable gloves and eye protection during handling.

⚠ Keep away from children and food products.

⚠ Prevent release into drains and natural waterways.

⚠ Store tightly closed in a cool, dry, well-ventilated location.

Packaging Options
1 Liter
5 Liter
20 Liter
25 Liter
200 Liter Drum
1000 Liter IBC

Applications

HVAC Systems
Chilled Water Systems
Heat Pumps
Process Cooling Equipment
Heat Recovery Systems
Ice Rink Refrigeration Systems
Industrial Heat Exchangers
Closed-Loop Cooling Systems
Commercial Building Cooling
Renewable Energy Cooling Systems

  • ✔ Ready-to-Use Premixed Formula
  • ✔ 42% Ethylene Glycol Content
  • ✔ Freeze Protection to Approximately –26°C
  • ✔ Corrosion Inhibitor Technology
  • ✔ Multi-Metal Protection
  • ✔ Excellent Heat Transfer Performance
  • ✔ Scale & Rust Protection
  • ✔ Long Service Life
Handling information

Safety & documents

Health Hazard Health Hazard Carcinogen, respiratory sensitizer, and target-organ risks.
Exclamation Mark Exclamation Mark Irritation, sensitization, or less severe acute hazards.

A Safety Data Sheet is not attached to this listing. Request the current SDS and handling information.

Product description

GlycoFlow 42 is a professional-grade premixed ethylene glycol coolant engineered for closed-loop heat transfer systems where reliable freeze protection, corrosion resistance, and efficient thermal performance are essential. The optimized 42% glycol concentration provides dependable low-temperature protection while maintaining excellent heat transfer characteristics for commercial and industrial applications.

Its advanced inhibitor technology helps protect ferrous and non-ferrous metals from corrosion, minimizes scale formation, and extends the service life of pumps, heat exchangers, piping, and associated cooling equipment. Because it is supplied ready to use, GlycoFlow 42 eliminates mixing errors, ensures consistent coolant quality, and simplifies maintenance for HVAC systems, chilled water circuits, industrial process cooling, heat recovery installations, and ice rink refrigeration systems. Properly inhibited ethylene glycol coolants are commonly used to provide freeze protection, corrosion control, and stable heat-transfer performance in closed-loop systems.

Client Chat

Discuss GlycoFlow 42 – Premixed Ethylene Glycol Antifreeze & Heat Transfer Coolant (42%) with our team

This conversation will stay linked with this page reference inside your client dashboard.

Chemical GlycoFlow 42 – Premixed Ethylene Glycol Antifreeze & Heat Transfer Coolant (42%) Reference page
Molecular structure
GlycoFlow 42 – Premixed Ethylene Glycol Antifreeze & Heat Transfer Coolant (42%) molecular structure
Water treatment support

Water treatment fit

A cooling-water hub for scale, corrosion, microbiological control, bleed-off, monitoring, and linked cooling tower product pages.

Scale & Deposit Control Inhibitors and dispersants are selected around hardness, cycles of concentration, heat load, and suspended solids.
Corrosion Protection Corrosion control must match metallurgy, pH, chlorides, operating temperature, and oxidizing chemistry.
Microbiological Control Biocide strategy should account for biofilm, algae, system volume, exposure risk, and monitoring frequency.
pH Conductivity Hardness Chloride Microbiological activity Corrosion coupon or visual checks
Client Quotation Form

Water treatment request for Cooling Tower Water Treatment Chemicals

Cooling water review needs makeup chemistry, cycles, conductivity target, metallurgy, basin condition, microbiology, and biocide/inhibitor program details.

Admin review needs
  • Cooling tower capacity, basin volume, circulation rate, and operating hours.
  • Makeup water analysis and current conductivity target.
  • Metallurgy details such as mild steel, copper, brass, stainless steel, or galvanized parts.
  • Current problems: scale, slime, algae, corrosion, odor, or high blowdown.
  • Current chemical names, dosing method, and monthly consumption.
Open Client Quotation Form Tap to share water analysis, product need, and site details
Report Focus Cooling Tower Water Treatment Recommendation Report

Cooling ranges depend on metallurgy, cycles, makeup chemistry, heat load, and biocide program. Use for screening before final site limits.

pH Conductivity Cycles of Concentration Total Hardness as CaCO3 Total Alkalinity as CaCO3 Chloride Residual Chlorine Microbiology / Bacteria Turbidity Calcium Hardness Silica
Category-specific judgment points
  • What are the tower capacity, basin volume, and circulation rate?
  • Which metallurgy is present: mild steel, galvanized, copper/brass, stainless, or mixed metals?
  • What conductivity/cycles target is currently used and how is bleed controlled?
  • Are algae, slime, microbiology, odor, or corrosion coupon issues visible?
Optional Water Analysis Parameters

Priority values are selected for Cooling Tower Water Treatment Chemicals. Fill any available lab or site values; uploads can carry the full report.

Use General Enquiry Portal
Frequently asked questions
What is GlycoFlow 42 – Premixed Ethylene Glycol Antifreeze & Heat Transfer Coolant (42%) and where is it supplied?

Grade: Industrial Grade. Available in Pakistan | Origin: Pakistan. Serving areas include Pakistan - all major cities.

What are the main applications of GlycoFlow 42 – Premixed Ethylene Glycol Antifreeze & Heat Transfer Coolant (42%)?

HVAC Systems Chilled Water Systems Heat Pumps Process Cooling Equipment Heat Recovery Systems Ice Rink Refrigeration Systems Industrial Heat Exchangers Closed-Loop Cooling Systems Commercial Building Cooling Renewable.

How can buyers request a quote for GlycoFlow 42 – Premixed Ethylene Glycol Antifreeze & Heat Transfer Coolant (42%)?

Use the quote or enquiry action on this page to send a Pakistan market enquiry directly: https://waterchemicalssolution.com/enquiry-portal/?enquiry_mode=physical&resource_id=49544&product_name=GlycoFlow%2042%20–%20Premixed%20Ethylene%20Glycol%20Antifreeze%20&%20Heat%20Transfer%20Coolant%20(42%)&type=Chemical&grade=Industrial%20Grade&market=Pakistan%20|%20Origin:%20Pakistan&serving_areas=Pakistan%20-%20all%20major%20cities